| | Overview
We assess the quantitative safety performance of safety-related systems in the railway, process and industrial control sectors against random hardware failures. The assessment demonstrates compliance with quantitative safety targets corresponding to the required Safety Integrity Level (SIL).
Based on international safety standards, we apply quantitative assessment methods, including failure rate prediction, reliability modelling, Fault Tree Analysis (FTA), Markov modelling and Common Cause Failure (CCF) analysis.
Taking account of system architecture, redundancy and fault-tolerant design, we calculate dangerous failure rates or probabilities and assess compliance with applicable quantitative safety targets, such as PFH, PFDavg and THR.
| | Major Subjects
-
Quantitative Safety Integrity Assessment
Analysis of dangerous failure rates and failure probabilities due to random hardware failures, and
assessment of compliance with quantitative safety targets corresponding to the required Safety Integrity
Level (SIL).
-
System Failure Modelling and Quantitative Analysis
Modelling of system failure logic and states using Fault Tree Analysis (FTA), Reliability Block Diagrams
(RBD) and Markov models. Quantitative safety assessment of redundant and fault-tolerant system
architectures.
-
Common Cause Failure (CCF) Analysis
Assessment of dependent failure probabilities in multi-channel systems using CCF models, including
Multiple Greek Letter (MGL), Alpha Factor and Beta Factor models, and evaluation of their effects on
system dangerous failure rates.
-
Quantitative Safety Target Demonstration
Comparison of analysis results with applicable quantitative safety targets, including PFH, PFDavg and
railway-specific THR/TFFR, to demonstrate compliance with the required safety objectives.
-
Quantitative Safety Demonstration Reporting
Preparation of quantitative safety demonstration reports documenting failure rate data, analysis models,
assumptions, calculation results and sensitivity analyses as supporting technical evidence.
| | Analysis Methods and Applicable Standards
-
Qualitative Risk Assessment Methods
Application of Risk Graph and Risk Matrix methods to assess accident severity, frequency of occurrence
and the possibility of avoiding harm, and to determine the required SIL.
-
Quantitative Risk Assessment Methods
Application of Layer of Protection Analysis (LOPA), Fault Tree Analysis (FTA) and probabilistic risk
assessment methods to evaluate hazardous event frequencies, required risk reduction and the adequacy of
safety targets.
-
Application of International Safety Standards
Risk assessment, SIL determination and allocation in accordance with applicable international safety
standards, including IEC 61508, IEC 61511, IEC 62278/EN 50126 and IEC 62425.

| | Key Deliverables
-
Failure Rate and Failure Mode Analysis Report
Component-level failure rate predictions, FMEA/FMEDA results, and assessments of dangerous failure
rates and diagnostic coverage.
-
Quantitative Safety Analysis Report
System safety analysis using FTA, RBD and Markov models, including calculated dangerous failure
probabilities and frequencies, taking account of redundancy, diagnostics and recovery characteristics.
-
Common Cause Failure (CCF) Analysis Report
Quantification of common cause failures using Beta Factor, Multiple Greek Letter (MGL) and Alpha Factor
models, including sensitivity analysis results.
-
Quantitative SIL Demonstration Report
Assessment of compliance with applicable quantitative safety targets, including TFFR under IEC 62425
and PFDavg and PFH under IEC 61508/61511. Documentation of analysis assumptions, input data,
calculation results, supporting evidence and conclusions.